In the Dell PowerEdge SC1435 servers delivered July 2008, there are several BIOS settings that need to be frobbed on setup. in the setup screen at F2: - CPU -> Virtualization Technology: on - Boot Sequence: disable NIC - Integrated Devices -> Embedded Gb NIC: turn off PXE - Serial Communication: - Serial Communication: On with Console Redirection via COM2 - External Serial Connector: COM1 - Failsafe Baud Rate: 57600 - Remote Terminal Type: VT100/VT220 - Redirection After Boot: Disabled New Supermicros: - Advanced -> "Wait for 'F1' If Error" -> Disabled - Advanced -> Power Button Function -> 4 Seconds Override - Advanced -> PCIe/PnP -> Load Onboard LAN N Option Rom -> Disabled - Advanced -> Serial Port -> SOL -> Redirection After BIOS Post -> BootLoader - Advanced -> Serial Port -> COM -> Console Redirection -> Enabled - Advanced -> Serial Port -> COM -> Redirection After BIOS Post -> BootLoader Advanced -> PCIe -> Disable all OPROMS - Boot order: USB Hard Disk, Removable, Hard Disk, UEFI Shell in the setup screen for remote management, at Ctrl-E: - Turn on IPMI over LAN - IP is (main IP) =~ s/18.181.0/10.5.128/ e.g. 10.5.128.221 for citadel-station == 18.181.0.221 - netmask is 255.255.0.0 - Set the password to the XVM root All of these settings are reflected on all 8 servers in the production cluster. In the debian installer: - 500M for /boot in raid1 of sda1, sdb1 - rest for LVM in raid1 of sda2, sdb2 - 50G / - 25G swap - install a vanilla kernel, not xen; will install xen hypervisor from backports in our later custom install. Currently allocated backend IPs: 10.5.128.16 c-s 10.5.128.17 a-s 10.5.128.18 s-m 10.5.128.19 a-m 10.5.128.20 d-o 10.5.128.21 g-d 10.5.128.22 b-f 10.5.128.23 m-a (not installed) 10.5.128.128 RAID group portal 10.5.128.129 RAID device/management 10.5.128.221 c-s IPMI 10.5.128.222 a-s IPMI 10.5.128.223 s-m IPMI 10.5.128.224 a-m IPMI 10.5.128.225 d-o IPMI 10.5.128.226 g-d IPMI (currently unplugged) 10.5.128.227 b-f IPMI 10.5.128.228 m-a IPMI (not configured) 18.4.58.231 new c-s IPMI 18.4.58.232 new a-s IPMI 10.6.128.16 c-s 10.6.128.17 a-s 10.6.128.18 s-m 10.6.128.19 a-m 10.6.128.20 d-o 10.6.128.21 g-d 10.6.128.22 b-f 10.6.128.23 m-a (not installed) 10.6.128.129 RAID device/management 10.6.128.229 g-d IPMI (temporary hardware)