5c13a6c6729c2e9daf91139a9847bcf6e09492c2
[invirt/doc/xvm.git] / xvm-host-setup-notes
1
2 In the Dell PowerEdge SC1435 servers delivered July 2008,
3 there are several BIOS settings that need to be frobbed on setup.
4
5 in the setup screen at F2:
6 - CPU -> Virtualization Technology: on
7 - Boot Sequence: disable NIC
8 - Integrated Devices -> Embedded Gb NIC: turn off PXE
9
10 in the setup screen for remote management, at Ctrl-E:
11 - IP is (main IP) =~ s/18.181.0/10.5.128/
12   e.g. 10.5.128.221 for citadel-station == 18.181.0.221
13
14 These settings are reflected in the basic screen of xvm-host-2 and the
15 remote-management screen of xvm-host-1.  At time of writing, the basic
16 settings on xvm-host-1 may differ, and the remote-management settings
17 on xvm-host-2 are disabled.  xvm-host-[34] remain in their shipping boxes.