Document IP address allocations
[invirt/doc/xvm.git] / xvm-host-setup-notes
index 0b45d16..1bc3914 100644 (file)
@@ -6,14 +6,64 @@ in the setup screen at F2:
 - CPU -> Virtualization Technology: on
 - Boot Sequence: disable NIC
 - Integrated Devices -> Embedded Gb NIC: turn off PXE
+- Serial Communication:
+  - Serial Communication: On with Console Redirection via COM2
+  - External Serial Connector: COM1
+  - Failsafe Baud Rate: 57600
+  - Remote Terminal Type: VT100/VT220
+  - Redirection After Boot: Disabled
 
 in the setup screen for remote management, at Ctrl-E:
+- Turn on IPMI over LAN
 - IP is (main IP) =~ s/18.181.0/10.5.128/
   e.g. 10.5.128.221 for citadel-station == 18.181.0.221
 - netmask is 255.255.0.0
+- Set the password to the XVM root
 
-These settings are reflected in the basic screen of xvm-host-2 and the
-remote-management screen of xvm-host-1.  At time of writing, the basic
-settings on xvm-host-1 may differ, and the remote-management settings
-on xvm-host-2 are disabled.  xvm-host-3 has IPMI-over-LAN enabled in
-the Ctrl-E screen.  xvm-host-4 remains unconfigured.
+All of these settings are reflected on all 8 servers in the production
+cluster.
+
+In the debian installer:
+ - 500M for /boot in raid1 of sda1, sdb1
+ - rest for LVM in raid1 of sda2, sdb2
+  - 50G /
+  - 25G swap
+ - install a vanilla kernel, not xen;
+   will install xen hypervisor from backports in our later custom install.
+
+
+Currently allocated backend IPs:
+
+10.5.128.16 c-s
+10.5.128.17 a-s
+10.5.128.18 s-m
+10.5.128.19 a-m
+10.5.128.20 d-o
+10.5.128.21 g-d
+10.5.128.22 b-f
+10.5.128.23 m-a (not installed)
+
+10.5.128.128 RAID group portal
+10.5.128.129 RAID device/management
+
+10.5.128.221 c-s IPMI
+10.5.128.222 a-s IPMI
+10.5.128.223 s-m IPMI
+10.5.128.224 a-m IPMI
+10.5.128.225 d-o IPMI
+10.5.128.226 g-d IPMI (currently unplugged)
+10.5.128.227 b-f IPMI
+10.5.128.228 m-a IPMI (not configured)
+
+10.6.128.16 c-s
+10.6.128.17 a-s
+10.6.128.18 s-m
+10.6.128.19 a-m
+10.6.128.20 d-o
+10.6.128.21 g-d
+10.6.128.22 b-f
+10.6.128.23 m-a (not installed)
+
+10.6.128.129 RAID device/management
+
+10.6.128.229 g-d IPMI (temporary hardware)