Document config for BIOS accessibility over IPMI
[invirt/doc/xvm.git] / xvm-host-setup-notes
1
2 In the Dell PowerEdge SC1435 servers delivered July 2008,
3 there are several BIOS settings that need to be frobbed on setup.
4
5 in the setup screen at F2:
6 - CPU -> Virtualization Technology: on
7 - Boot Sequence: disable NIC
8 - Integrated Devices -> Embedded Gb NIC: turn off PXE
9 - Serial Communication:
10   - Serial Communication: On with Console Redirection via COM2
11   - External Serial Connector: COM1
12   - Failsafe Baud Rate: 57600
13   - Remote Terminal Type: VT100/VT220
14   - Redirection After Boot: Disabled
15
16 in the setup screen for remote management, at Ctrl-E:
17 - Turn on IPMI over LAN
18 - IP is (main IP) =~ s/18.181.0/10.5.128/
19   e.g. 10.5.128.221 for citadel-station == 18.181.0.221
20 - netmask is 255.255.0.0
21 - Set the password to the XVM root
22
23 All of these settings are reflected on all 4 servers in the production
24 cluster.
25
26
27 In the debian installer:
28  - 500M for /boot in raid1 of sda1, sdb1
29  - rest for LVM in raid1 of sda2, sdb2
30   - 50G /
31   - 25G swap
32  - install a vanilla kernel, not xen;
33    will install xen hypervisor from backports in our later custom install.
34