2 In the Dell PowerEdge SC1435 servers delivered July 2008,
3 there are several BIOS settings that need to be frobbed on setup.
5 in the setup screen at F2:
6 - CPU -> Virtualization Technology: on
7 - Boot Sequence: disable NIC
8 - Integrated Devices -> Embedded Gb NIC: turn off PXE
9 - Serial Communication:
10 - Serial Communication: On with Console Redirection via COM2
11 - External Serial Connector: COM1
12 - Failsafe Baud Rate: 57600
13 - Remote Terminal Type: VT100/VT220
14 - Redirection After Boot: Disabled
17 - Advanced -> "Wait for 'F1' If Error" -> Disabled
18 - Advanced -> Power Button Function -> 4 Seconds Override
19 - Advanced -> PCIe/PnP -> Load Onboard LAN N Option Rom -> Disabled
20 - Advanced -> Serial Port -> SOL -> Redirection After BIOS Post -> BootLoader
21 - Advanced -> Serial Port -> COM -> Console Redirection -> Enabled
22 - Advanced -> Serial Port -> COM -> Redirection After BIOS Post -> BootLoader
23 - Advanced -> PCIe -> Disable all OPROMS
24 - IPMI -> BMC Network Configuration
25 - Boot order: USB Hard Disk, Removable, Hard Disk, UEFI Shell
28 - 1000M for /boot in raid1 of sda1, sdb1
29 - rest for LVM in raid1 of sda2, sdb2
32 - install a vanilla kernel, not xen;
33 will install xen hypervisor from backports in our later custom install
35 in the setup screen for remote management, at Ctrl-E:
36 - Turn on IPMI over LAN
37 - IP is (main IP) =~ s/18.181.0/10.5.128/
38 e.g. 10.5.128.221 for citadel-station == 18.181.0.221
39 - netmask is 255.255.0.0
40 - Set the password to the XVM root
42 All of these settings are reflected on all 8 servers in the production
45 In the debian installer:
46 - 500M for /boot in raid1 of sda1, sdb1
47 - rest for LVM in raid1 of sda2, sdb2
50 - install a vanilla kernel, not xen;
51 will install xen hypervisor from backports in our later custom install.
54 Currently allocated backend IPs:
63 10.5.128.23 m-a (not installed)
65 10.5.128.128 RAID group portal
66 10.5.128.129 RAID device/management
73 10.5.128.226 g-d IPMI (currently unplugged)
75 10.5.128.228 m-a IPMI (not configured)
76 18.4.58.231 new c-s IPMI
77 18.4.58.232 new a-s IPMI
78 18.4.58.233 new s-m IPMI
79 18.4.58.234 new a-m IPMI
89 10.6.128.23 m-a (not installed)
91 10.6.128.129 RAID device/management
93 10.6.128.229 g-d IPMI (temporary hardware)